Installation and maintenance manualCOCINAS CRISTAL-GAS CG.1 4G / CG.1 3G. 1PCG Lux-60 4G. / CG Lux-70 4G. / CG Lux-70 4G AI ALCG Lux-70 5G. / CG Lux-6
Positioning of the ovenSee the applicable manual.Once the hob position has been dimensioned,the seal (J) must be affixed to the lower partof the cooke
Hob models CG-Lux-75 2G and CG-Lux-86 3Ga re installed in the same way as the CGC 4GAI AL, except for the staples which aregeometrically diff
Rear view of the Control Panel:Flexible Power Cable.Connector.Power Unit Protective Casing.6 Position the oven in its definitive location,ensuring th
T E K A will not accept responsability for faultsor damage caused by incorrect or defectiveinstalation.Once the gas connetion has been made thea i rt
Important!The transformation of the appliance to use ad i ff e r ent gas to that for which it has beensold must only be carried out by a qualifiedtech
• In order to access the screw which gradua-tes the gas flow through the taps in hobCGC 4G AI AL, remove the screws that fixthe cover protecting the t
16Dimensions and powersModels CG.1 4G CG.1 3G. 1P.CG Lux-60CG Lux-60 CGCCGC 4GCG Lux-70 4G AI AL4G. 4GAI AL4G.Dimensions in mmLength 590 590 610 610 6
17ModelsCG Lux-70CG Lux-70CG Lux-70 CG Lux-70CG Lux-70CG Lux-75 CG Lux-86 CG Lux-864G AI AL5G.5G AI AL 5G AI TR AL5G. TR2G AI TR AL 3G AI TR AL2G 1P A
18COMMON CHARACTERISTICS TO THE ELEC-TRIC HOTPLATES AND AUTOMATIC LIGHTINGMODELThe supply voltage and frequency must be those indicated in the rating
COMMON CHARACTERISTICS TO EVERYMODELN.B.: All the hob models re f e r red to in thismanual have hot zones during or after theiruse and can cause bu
Dear Customer,Thank you for choosing a TEKA hob.We are sure that our product will fully satisfyyour requirements.This modern, functional and practical
20T E K A INDUSTRIAL, S.A.SANTANDER - ESPAÑAMod.CG.1 4GG-110 Vr Nm3/h G-20 VrNm3/h1.70 0.71G-130 Vr Nm3/h G-25 VrNm3/h1.05 0.83G-150 VrES FRNm3/h G-30
21T E K A INDUSTRIAL, S.A.SANTANDER - ESPAÑAMod.CG LUX 70 5GG-110 Vr Nm3/h G-20 VrNm3/h2.38 1.00G-130 Vr Nm3/h G-25 VrNm3/h1.47 1.16G-150 VrES FRNm3/h
22T E K A INDUSTRIAL, S.A.SANTANDER - ESPAÑAMod.CGC 4GG-110 Vr Nm3/h G-20 VrNm3/h1.70 0.71G-130 Vr Nm3/h G-25 VrNm3/h1.05 0.83G-150 VrES FRNm3/h G-30
23T E K A INDUSTRIAL, S.A.SANTANDER - ESPAÑAMod.CG LUX 70 5G AITR A LCG LUX 70 AI TRG-110 Vr Nm3/h G-20 VrNm3/h2.50 1.04G-130 Vr Nm3/h G-25 VrNm3/h1.5
Before connecting the hob to the power supplycheck that the voltage and frequency are tho-se indicated in the rating plate located on thelower part of
For hobs CG Lux-60, CG Lux-70, CG Lux-75and CG Lux-86, which have automatic igni-tion and a safety feature, the following stepsshould be followed: (Se
Use flat bottomed pans and check that theya re placed correctly on the pan support, ino rder to prevent pans from sliding when theircontents start to
27On all the hobs which incorporate the safetyf e a t u re (models with initials AL), the gas cut-o ff system is comprised formed by the follo-wing el
28• When cooking with a griddle pan, stonewa-re pots or pans which reflect heat down-wards, you must use the pan support sup-plement, otherwise the
• Do not use large burners with pans ofsmall diameters as part of the flame willbe deflected around the outside of thepan, thus considerably redu
Introduction Page 4Description of the Appliance 4Installation 9Positioning of the hobs 9Positioning of the oven 10Anchoring of the hob 10Connecting th
Do not use small pans on large burners, as the fla-me will be dissipated.Use appropriately sized pans for each burn e r, thusmaking the best use of th
For the correct conservation of the hob glassit must be cleaned using the appropriate pro-ducts and utensils and when the glass iscold. Cleaning is ea
B e f o re cleaning, disconnect the appliancefrom the mains supply.Electric hotplates should be cleaned withsoapy water and a non-abrasive sc
33Fault Possible Cause SolutionNeither the hob nor the pilot light works.The mains cable is not connected. Connect the mains cable.No spark appears wh
Teka Industrial, S. A.Cajo, 17 39011 SANTANDER (SPAIN)Tel.: 34 - 942 35 50 50Fax: 34 - 942 34 76 94http://www.teka.netTeka Küchentechnlk GmbHSechsheld
CG. 1 4G (see drawing 1)1 Auxiliary burner of 860 Kcal/h - 1 kW.2 Semi fast burner of 1,500 Kcal/h - 1.75 kW.3 Fast burner of 2,550 Kcal/h - 3 k
CG-Lux-60 4G. and CG Lux-60 4G AI AL ( s e edrawing 3)1 Fast burner of 2,580 Kcal/h - 3 kW.2 Semi fast burner of 1,500 Kcal/h - 1.75 kW.3 Semi
CG-Lux-70 5G., and CG Lux -70 5G AI AL (Seedrawing 5)1 Fast burner of 2,580 Kcal/h - 3 kW.2 Fast burner of 2,580 Kcal/h - 3 kW.3 Semi fast burner o
7CG-Lux-70 4G and CG Lux -70 4G AI AL(See drawing 7)1 Fast burner of 2,580 Kcal/h - 3 kW.2 Semi fast burner of 1,500 Kcal/h - 1.75 kW.3 Semi f
CG-Lux-86 3G AI TR AL (See drawing 9)1 Triple ring burner of 3,010 Kcal/h - 3.5 kW.2 Triple ring burner of 3,010 Kcal/h - 3.5 kW.3 Semi f
I N S TA L L ATION AND ADJUSTMENT MUST BECARRIED OUT BY AUTHORISED TECHNICALPERSONNEL ACCORDING TO THE APPLICABLEINSTALLATION REGULATIONS.Depending